Water Treatment Glossary: 57 Terms in Plain English

The short of it

A softener or filter listing mixes chemistry, plumbing and certification words. This glossary defines 57 of them in plain English, with the number that matters and the source behind it: the USGS, Penn State Extension, the EPA and the NSF.

By the Best Water Softener Picks desk · Checked · How we research

Jump to a group
  1. Hardness and units
  2. How a softener works
  3. Salt-free conditioners
  4. Filters and reverse osmosis
  5. Well water
  6. Certifications and reports

Hardness and units

Water check

Hardness is calcium and magnesium expressed as calcium carbonate. Labs report it in mg/L or ppm, softener makers in grains per gallon, and 1 gpg is about 17.1 mg/L.

Hard water

Water with a high level of dissolved calcium and magnesium. The USGS calls water moderately hard from 61 to 120 mg/L, hard from 121 to 180 mg/L and very hard above 180 mg/L. Hardness is not a health risk; it leaves scale and spots. See what is hard water.

Grain

An old unit of weight equal to 1/7,000 of a pound, about 64.8 milligrams. Softener capacity is counted in grains of hardness removed between two regenerations.

Grains per gallon (gpg)

The hardness unit softener makers use. One grain per gallon is about 17.1 mg/L, according to Penn State Extension. Convert any reading with the hardness converter.

ppm and mg/L

Parts per million and milligrams per liter. For water they are the same number, because a liter of water weighs about a million milligrams. City water reports and labs use them.

Calcium carbonate equivalent (as CaCO3)

The way labs add calcium and magnesium into one hardness figure: each is converted to the weight of calcium carbonate it would form. "Total hardness as CaCO3" is the line to read on a report.

French and German degrees (°f, °dH)

European hardness units. One French degree is 10 mg/L of calcium carbonate; one German degree is about 17.85 mg/L. Dishwasher and espresso machine manuals often use them.

Total dissolved solids (TDS)

Everything dissolved in the water, in mg/L: hardness minerals, sodium, chloride, sulfate and more. The EPA's secondary standard for TDS is 500 mg/L (EPA). A TDS meter cannot tell you what the solids are.

Scale

The hard white crust that calcium carbonate leaves when water is heated or evaporates: inside water heaters, on faucets, in kettles and shower heads.

How a softener works

Water check

A salt-based softener passes water through resin beads that trade sodium for calcium and magnesium, then rinses the beads with brine when they are full.

Ion exchange

The process inside a softener: the resin holds sodium (or potassium) ions and releases them as it captures calcium and magnesium ions. It removes hardness rather than hiding it.

Resin

The small plastic beads in the softener's main tank that do the ion exchange. Resin wears out over years, faster with chlorine or iron in the water. See water softener resin.

Mineral tank

The tall tank that holds the resin. Its size, often given in cubic feet of resin, sets the softener's capacity.

Brine tank

The second tank, filled with salt and some water. It makes the salty brine that recharges the resin. See the brine tank guide.

Regeneration

The cycle that recharges the resin: a backwash, a brine draw, a rinse and a refill of the brine tank. Most softeners run it at night, when nobody uses water.

Capacity

The number of grains a softener can remove between two regenerations, such as 32,000 or 48,000 grains. Makers rate it at their highest salt setting. Size yours with the size calculator.

Salt efficiency

Grains of hardness removed per pound of salt. NSF/ANSI 44 lets a softener claim an efficiency rating only if it removes at least 3,350 grains per pound of salt.

Metered (demand-initiated) regeneration

A control valve that counts the gallons used and regenerates only when the resin is nearly full. It uses less salt and water than a timer that regenerates on fixed days.

Control valve

The head on top of the mineral tank that runs the cycles and sends water through the resin or around it. Fleck and Clack are common valve makers.

Bypass valve

A valve that lets water skip the softener, for repairs or for an outdoor tap that does not need soft water. See the bypass loop guide.

Backwash

Water run upward through a tank to loosen the bed and flush trapped dirt to the drain. Softeners, iron filters and carbon tanks all backwash.

Twin-tank softener

Two mineral tanks that take turns, so one is always in service while the other regenerates. It suits large households and very hard water.

Salt bridge

A hard crust of salt that forms in the brine tank, leaving a hollow space under it. The softener then makes no brine and stops softening. See salt bridges.

Potassium chloride

A salt substitute for softeners. It adds potassium instead of sodium, costs more, and some makers raise the salt setting for it. See potassium vs sodium softener salt.

Salt-free conditioners

Water check

A salt-free conditioner does not remove hardness. It aims to stop scale from sticking, so a hardness test reads the same before and after.

Salt-free conditioner

A tank that treats water without salt, a drain or a brine tank. It does not soften water; its claim is less scale. Read do salt-free water softeners work.

TAC (template assisted crystallization)

The most common salt-free method: a media that turns dissolved hardness into tiny crystals that stay in the water instead of forming scale on surfaces. See TAC water conditioners.

Magnetic and electronic descalers

Devices clipped or wrapped around a pipe that claim to change how minerals behave. Evidence for them is weaker than for TAC; see magnetic and electronic softeners.

Filters and reverse osmosis

Water check

Filters remove what softeners leave: sediment, chlorine and chloramine, lead, PFAS. Reverse osmosis removes most dissolved solids, including hardness, at a single tap.

Point of entry (POE)

A system that treats all the water entering the home, such as a softener or a whole-house filter.

Point of use (POU)

A system that treats water at one tap, such as an under-sink filter, a pitcher or a reverse osmosis faucet.

Sediment filter

A cartridge or tank that catches sand, silt and rust. It protects the equipment after it. See whole-house sediment filters.

Micron rating

The size of particle a filter stops, in thousandths of a millimeter. A 5-micron sediment cartridge stops finer grit than a 50-micron screen. "Nominal" means most particles of that size; "absolute" means nearly all.

Activated carbon

Carbon with a huge internal surface that adsorbs chlorine, many tastes and odors, and some chemicals. Block carbon filters finer than loose granular carbon.

Catalytic carbon

Activated carbon treated to speed up chemical reactions on its surface. It is the usual choice for chloramine and for hydrogen sulfide.

KDF

A media of copper and zinc granules that reduces chlorine through an oxidation and reduction reaction. It is common in shower filters, often paired with carbon.

Chloramine

A disinfectant made from chlorine and ammonia that many US cities use because it lasts longer in the pipes. It is harder to remove than chlorine and calls for catalytic carbon. See filters for chlorine and chloramine.

PFAS

Per- and polyfluoroalkyl substances, man-made chemicals that persist in the environment. In April 2024 the EPA set national drinking water limits that include 4.0 parts per trillion for PFOA and for PFOS; check the EPA PFAS page for the current rule and dates. See filters for PFAS.

Reverse osmosis (RO)

Water pushed through a membrane fine enough to hold back most dissolved salts, metals and many chemicals. The rejected water goes to the drain. See what reverse osmosis is.

RO membrane

The rolled sheet inside a reverse osmosis system that does the separation. Carbon prefilters protect it from chlorine, which damages most membranes.

Gallons per day (GPD)

The rated output of a reverse osmosis system over 24 hours. Tankless systems with a high GPD fill a glass faster.

Gallons per minute (GPM)

The flow a whole-house system can deliver. A unit with too low a GPM rating drops your shower pressure when several taps run at once.

Remineralization

A final cartridge that adds a little calcium and magnesium back after reverse osmosis, mostly for taste.

Well water

Water check

Private wells are not covered by federal drinking water rules, so the owner tests and treats. Iron, manganese, sulfur, pH and bacteria each have their own fix.

Coliform bacteria

A group of bacteria used as a warning sign that surface water or waste may be reaching the well. The EPA advises testing for total coliform at least once a year.

Shock chlorination

A one-time dose of chlorine into the well and plumbing to kill bacteria, followed by a retest. It does not fix the way the bacteria got in.

UV disinfection

An ultraviolet lamp in a steel chamber that inactivates bacteria and viruses as water flows past. It adds nothing to the water and does not remove chemicals. Try the well water treatment finder.

UV dose

The amount of UV energy delivered, in millijoules per square centimeter (mJ/cm2). NSF/ANSI 55 Class A systems deliver at least 40 mJ/cm2.

Iron filter (air injection oxidation)

A tank that oxidizes dissolved iron, manganese and hydrogen sulfide, often with a pocket of air, then traps the particles in a media bed and backwashes them away. See iron filters for well water.

Greensand

A filter media coated with manganese oxide that oxidizes and traps iron, manganese and hydrogen sulfide.

Hydrogen sulfide

A gas that gives well water a rotten egg smell. See removing sulfur smell from well water.

Acid neutralizer

A tank of calcite (crushed calcium carbonate), sometimes blended with magnesium oxide, that dissolves slowly and raises the pH of acidic well water. It adds hardness, so it goes before a softener. See acid neutralizing filters.

Certifications and reports

Water check

A filter claim means something only when the model is listed for that claim. NSF/ANSI 42, 53, 58 and 401 cover filters, 44 covers softeners and 55 covers UV.

NSF/ANSI 42

The standard for aesthetic effects: chlorine taste and odor, and particulates. It says nothing about health contaminants.

NSF/ANSI 53

The standard for health effects, such as lead, cysts, some volatile organic chemicals, and PFOA and PFOS. Check which contaminants a model is listed for, since a certificate covers named claims only.

NSF/ANSI 58

The standard for reverse osmosis systems, covering contaminant reduction and the efficiency rating, the share of incoming water that ends up as drinking water.

NSF/ANSI 401

The standard for emerging contaminants, such as some pharmaceuticals, herbicides and bisphenol A, at low levels.

NSF/ANSI 44

The standard for residential softeners: capacity claims, salt efficiency, and the build of the unit.

NSF/ANSI 55

The standard for UV systems. Class A covers disinfection of clear water; Class B is supplemental treatment of water already considered safe.

NSF P231

An NSF protocol for microbiological water purifiers, which must reduce bacteria, viruses and cysts. It is common on portable and emergency purifiers.

WQA Gold Seal

The product certification mark of the Water Quality Association, which tests products against the same ANSI standards. Check a model in the WQA listings; for NSF, use the NSF database.

Consumer Confidence Report (CCR)

The yearly water quality report every community water system sends its customers. It lists what was found in the water, including hardness on many reports (EPA).

MCL and secondary standard

An MCL (maximum contaminant level) is an enforceable EPA limit for public water systems. A secondary standard, such as 0.3 mg/L for iron, is a non-enforceable guideline for taste, odor, color or stains.

Sources

Our sources by topic

Public agencies and universities

Certification and standards bodies